All Products >> Standardized Powerline >>Echelon CPD3000

Product Details

Key characteristics of the Echelon power line control system:

  • Field communication technology: LonWorks standardized ISO14908 protocol over power line
  • IPv6 addressing: No
  • Number of end-device per gateway: 150
  • Data transfer rate and bandwidth : < 5 kbits/second
  • Supports dynamic lighting with occupancy/presence sensors (real time) : Yes
  • Supports dynamic lighting with traffic counting: Yes, through Streetlight.Vision CMS
  • Dimming interface : 1-10 Volts
  • Metering data produced/collected : lamp level, lamp command, voltage, current, power, power factor, energy, lamp running hours, temperature
  • Failure data produced/collected : lamp failure, low power factor, high/low power, high/low voltage, high/low current
  • Streetlight.Vision CMS support
    • Real time control: Yes
    • Data collect: Yes
    • Alarming: Yes
    • Switching/dimming schedulers and calendars: Yes
    • Alarming: Yes
    • Commissioning: Yes
    • Over-the-air firmware upgrade for light point controllers: Yes